hitrap fibro prisma columns Search Results


92
GE Healthcare hitrap mabselect prisma columns
Hitrap Mabselect Prisma Columns, supplied by GE Healthcare, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap mabselect prisma columns/product/GE Healthcare
Average 92 stars, based on 1 article reviews
hitrap mabselect prisma columns - by Bioz Stars, 2026-03
92/100 stars
  Buy from Supplier

86
Danaher Inc proteina column
Proteina Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/proteina column/product/Danaher Inc
Average 86 stars, based on 1 article reviews
proteina column - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap abselect prisma protein a column
Hitrap Abselect Prisma Protein A Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap abselect prisma protein a column/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap abselect prisma protein a column - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap fibro prisma
Hitrap Fibro Prisma, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap fibro prisma - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap fibro prisma device
Hitrap Fibro Prisma Device, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma device/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap fibro prisma device - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

90
Danaher Inc hitrap fibro prisma columns
Hitrap Fibro Prisma Columns, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma columns/product/Danaher Inc
Average 90 stars, based on 1 article reviews
hitrap fibro prisma columns - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

86
Danaher Inc hitrap mabselect prisma protein a affinity column
Hitrap Mabselect Prisma Protein A Affinity Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap mabselect prisma protein a affinity column/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap mabselect prisma protein a affinity column - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap fibro prisma membrane device
Hitrap Fibro Prisma Membrane Device, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma membrane device/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap fibro prisma membrane device - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap tm mabselect tm prisma column
Hitrap Tm Mabselect Tm Prisma Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap tm mabselect tm prisma column/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap tm mabselect tm prisma column - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap fibro prisma membrane
Hitrap Fibro Prisma Membrane, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma membrane/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap fibro prisma membrane - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Danaher Inc hitrap fibro prisma column
Hitrap Fibro Prisma Column, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hitrap fibro prisma column/product/Danaher Inc
Average 86 stars, based on 1 article reviews
hitrap fibro prisma column - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

86
Sartorius AG sartobind protein
Flow rate versus residence time for all Protein A stationary phases.
Sartobind Protein, supplied by Sartorius AG, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sartobind protein/product/Sartorius AG
Average 86 stars, based on 1 article reviews
sartobind protein - by Bioz Stars, 2026-03
86/100 stars
  Buy from Supplier

Image Search Results


Flow rate versus residence time for all Protein A stationary phases.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Flow rate versus residence time for all Protein A stationary phases.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques:

Normalized breakthrough curves from loading hIgG at 5 mg/mL onto Protein A membranes. Flow rate was varied from 5 to 120 s residence time for all stationary phases. ( A ) Cytiva HiTrap Fibro™ PrismA, ( B ) Purilogics Purexa™ PrA, ( C ) Gore ® Protein Capture Device, ( D ) Sartorius Sartobind ® Protein A, ( E ) summary of measured DBC 10 for all stationary phases. (The dotted lines are guides to the eye).

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Normalized breakthrough curves from loading hIgG at 5 mg/mL onto Protein A membranes. Flow rate was varied from 5 to 120 s residence time for all stationary phases. ( A ) Cytiva HiTrap Fibro™ PrismA, ( B ) Purilogics Purexa™ PrA, ( C ) Gore ® Protein Capture Device, ( D ) Sartorius Sartobind ® Protein A, ( E ) summary of measured DBC 10 for all stationary phases. (The dotted lines are guides to the eye).

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques:

Langmuir adsorption isotherms for Purilogics Purexa™ PrA and Sartorius Sartobind ® Protein A membranes. Symbols represent experimental data and the curves represent fitted data with Langmuir adsorption parameters. Langmuir adsorption parameters are listed in for both membrane devices.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Langmuir adsorption isotherms for Purilogics Purexa™ PrA and Sartorius Sartobind ® Protein A membranes. Symbols represent experimental data and the curves represent fitted data with Langmuir adsorption parameters. Langmuir adsorption parameters are listed in for both membrane devices.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques: Adsorption, Membrane

Langmuir adsorption isotherm parameters for hIgG static adsorption onto Protein A stationary phases.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Langmuir adsorption isotherm parameters for hIgG static adsorption onto Protein A stationary phases.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques: Adsorption

Physical properties of all Protein A stationary phases.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Physical properties of all Protein A stationary phases.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques: Membrane, Permeability

Elution behavior for Protein A membrane adsorbers at 12 and 120 s residence time. Membranes were saturated using 2 mg/mL hIgG in 1X PBS pH 7.4 buffer and eluted using 0.1 M citric acid pH 3 buffer. ( A ) Cytiva HiTrap Fibro™ PrismA, ( B ) Purilogics Purexa™ PrA, ( C ) Gore ® Protein Capture Device, ( D ) Sartorius Sartobind ® Protein A, ( E ) summary of measured EVs for all stationary phases at both flow rates, with the membrane to dead volume ratio graphed on the secondary y -axis.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Elution behavior for Protein A membrane adsorbers at 12 and 120 s residence time. Membranes were saturated using 2 mg/mL hIgG in 1X PBS pH 7.4 buffer and eluted using 0.1 M citric acid pH 3 buffer. ( A ) Cytiva HiTrap Fibro™ PrismA, ( B ) Purilogics Purexa™ PrA, ( C ) Gore ® Protein Capture Device, ( D ) Sartorius Sartobind ® Protein A, ( E ) summary of measured EVs for all stationary phases at both flow rates, with the membrane to dead volume ratio graphed on the secondary y -axis.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques: Membrane

Tailing ratio of Protein A membrane adsorbers at 12 s and 120 s RT.

Journal: Membranes

Article Title: Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies

doi: 10.3390/membranes13050511

Figure Lengend Snippet: Tailing ratio of Protein A membrane adsorbers at 12 s and 120 s RT.

Article Snippet: The tailing ratio for Purilogics Purexa™ PrA, Cytiva HiTrap Fibro™ Prism A, and Sartorius Sartobind ® Protein A show a significant increase at 12 s RT versus 120 s RT.

Techniques: Membrane